infusion pump

infusion pump
Product Detailed
Three kind s of infusion mode: Rate, Time and Body Weight

Function and Features

l Three kinds of modes: Rate Mode, Time Mode, Body Weight Mode.

l Unique door free structure: Avoiding problems of pump stuck and fluid leakage.

l Double CPU: Making the process of infusion safer and more reliable.

Accurate Injection: Precise control of the infusion rate and infusion volume. 

l Flow rate range: 1.0 ml/h-2000.0 ml/h.

l Driven by step motor: No pulsating wave will be educed even during low-rate 

injection.

l Alarm is given in the following situations: Infusion Completion, Occlusion,

 Low Battery, Air Bubble, Installation Error, Malfunction or Operation Error.

l IV Set: All brands of standard IV sets are compatible.

l KVO rate can be selectable according to concrete requirements from 1.0 ml/h to 5.0 ml/h.  

l Wireless Module Control: When used with 2000I or 900I, the infusion information will be transferred to the Infusion Supervision System in order to ensure the patients’ safety. 

l Big Color LCD.

Technical Parameters of H-075 Infusion pump

Dimension

120×140×195 mm

 

Accumulated infusion volume

1.0~9999.0 ml

Maximum weight

2.0 kg

Infusion accuracy

±3%

Displayed information

RATE

VOL.LIMIT

∑( accumulated infusion volume)

Battery charge indicator

AC power indicator

Over

OCCL.

AIR

BED No.

Alarm function

Over

OCCL.

Low battery

IV line installation error

AIR

EMPTY

Machine malfunction

Fuse

T 2AL 250V~

KVO rate

1.0 ml/h-5.0 ml/h

Maximum power 

consumption

25VA, running more than 4 hours 

after being charged

Selectable modes

Rate mode, Time mode, Weight

 mode

Infusion rate range

1.0-2000 ml/h

Rate mode

1.0~2000.0 ml/h

Bolus

Rate:≤1000.0 ml/h

Bolus: 1000.0 ml/h

Time mode

Volume limit: 0.1~999.9ml 

 Time: 1~2000 minutes

Operation conditions

Environment temperature 5°C~40°C, air pressure 86kPa~106kPa,

 relative  humidity ≤80%

Body Weight mode

Drug limit: 1.0~999.9 mg, Volume 

limit: 0.1~999.9 ml. Weight:

 0.1~300.0 kg, Dose: 0.1~9999.9

Selectable unit: mg/kg/h, ug/kg/min

Electrical Safety

Comply with EN60601-1 for medical equipment and 

EN60601-2-24

Battery

Rechargeable lithium polymer 

battery, 7.4V, 1600 mA

Applicable infusion sets

All standard IV sets

Storage

Environment temperature-20~55°C, air pressure 50~106kPa, relative 

humidity ≤95%

                                                                        